Definition
A cardiac cycle is one ventricular contraction (systole, 0.34 s at rest) and relaxation (diastole, 0.66 s), divided into five steps by valves that open and close passively. Each ventricle fills to about 130 mL, empties to about 60 mL and so ejects 70 mL, equally on both sides but at lower pressure on the right. Closure of the atrioventricular (AV) valves makes the first heart sound (S1), and closure of the semilunar valves the second (S2).
1. The pump and its valves
The heart is a muscular organ inside the pericardium, its enclosing sac, and its wall of cardiac muscle cells is the myocardium. It has right and left sides, each with an atrium and a ventricle, and its valves are held in a fibrotendinous ring.
Between each atrium and its ventricle lies an atrioventricular (AV) valve, the tricuspid valve on the right and the mitral valve on the left. The free margins of its cusps are tied by tendinous cords, the chordae tendineae, to the papillary muscles, which are projections of the ventricular muscle. When the ventricle contracts, the papillary muscles contract with it and pull the cords taut, which prevents eversion, in other words stops the cusps being forced back into the atria. As a result, blood can pass only from atrium to ventricle.The semilunar valves, aortic (left ventricle to aorta) and pulmonary (right ventricle to pulmonary artery), let blood into the arteries in systole (ventricular contraction) and stop back-flow in diastole (relaxation). All valves open and close passively on the pressure difference across them, and together they make flow through the heart one-way.
2. What a cardiac cycle is
The length of a cycle is simply 60 seconds divided by the heart rate, cycle length (s) = 60 / heart rate (beats per minute), so 60/60 = 1.0 s and 60/180 = 0.33 s. A rate of 120 per minute therefore gives 60/120 = 0.5 s, and a cycle of only 0.25 s would need 240 beats per minute.
Between rest and maximum rate, diastole loses 0.53 s but systole only 0.14 s, because the two phases are timed differently. Systole lasts roughly as long as the ventricular action potential and the contraction it triggers (Cardiac Action Potential – Resting Potential, Phases and Refractory Period), and these shorten only modestly as the rate rises. Diastole, by contrast, is simply the time left before the next beat begins, so most of the time saved by beating faster comes out of diastole. Because diastole is when the ventricles fill, this costs filling time. Little is lost at first, because most filling happens quickly in early diastole, but at the highest rates the ventricle fills less and so ejects less with each beat.
3. Diastole in three steps
Diastole begins with isovolumetric (isometric) ventricular relaxation, a very short phase (0.05 s) in which all valves are shut, so the relaxing ventricle has no flow and no change in volume, and therefore none in fibre length, which is what the two names mean. Its volume is at the minimum, the end-systolic volume (ESV). Atrial pressure is still lower than ventricular, but returning blood fills the atrium until its pressure exceeds ventricular pressure and the AV valve opens passively, beginning ventricular filling.
Filling lasts about 0.5 s at rest and is about 80% passive, down the pressure gradient. In late diastole the atria depolarise (the P wave of the ECG) and contract, raising atrial pressure to about 5 mmHg and pushing in the final 20%, so volume peaks at the end-diastolic volume (EDV), about 130 mL at rest (CVS6 uses 140 mL). Atrial contraction is therefore the last event of diastole, not the start of systole.
4. Systole in two steps
Systole opens as the ventricles depolarise (the QRS complex) and contract, their tension raising left ventricular pressure (LVP) above atrial pressure, so the mitral valve rapidly closes, which gives the first heart sound (S1) and begins isovolumetric (isometric) contraction (0.05 s). With AV and semilunar valves all closed volume cannot change, so pressure rises steeply, never falls, until it can overcome aortic pressure.
Ejection (0.3 s) starts when LVP exceeds aortic pressure (AP) and the aortic valve opens, the opening of the semilunar valves marking the start of ejection. Blood entering the aorta raises arterial volume and pressure, LVP and AP rise in parallel to a maximum at mid-systole, and about two-thirds of the blood leaves in the first third of ejection (rapid ejection). In late systole (reduced ejection) both pressures fall, the ventricles repolarise (the T wave) and volume reaches ESV. Isovolumetric contraction (0.05 s) is thus far shorter than ejection (0.3 s).
5. Closing the loop
When ventricular pressure falls below aortic, the semilunar valves close, giving the second heart sound (S2) with aortic (A) and pulmonary (P) components. This closure marks the end of systole and the beginning of diastole, and the cycle re-enters isovolumetric relaxation at an ESV of about 60 mL.
Followed round the whole cycle, ventricular volume is maximal at EDV, falls in ejection to its minimum at ESV and is constant in both isovolumetric phases. Ventricular pressure is lowest at the start of diastole and rises a little with filling and atrial contraction, then rises dramatically in isovolumetric contraction to a maximum in ejection, falls in late systole and falls dramatically in isovolumetric relaxation. Arterial pressure is lowest at the end of diastole (the diastolic pressure) and peaks with ventricular pressure in ejection (the systolic pressure). It dips at the incisura or dicrotic notch when the aortic valve closes, a brief dip as back-flow snaps the valve shut, and then falls through diastole to its diastolic minimum.
The two volumes give the stroke volume, SV = EDV - ESV = 130 - 60 = 70 mL, and the ejection fraction, EF = SV / EDV, about 54%.
6. The numbers for both sides
The right side of the heart, the right atrium and ventricle that pump blood to the lungs, runs essentially the same events as the left, and the resting numbers show what differs.
| Chamber or vessel | Diastole | Systole |
|---|---|---|
| Left ventricle | 0 mmHg | 120 mmHg |
| Aorta | 80 mmHg | 120 mmHg |
| Right ventricle | 0 mmHg | 25 mmHg |
| Pulmonary artery | 8 mmHg | 25 mmHg |
| Ventricular volume, left = right | EDV 130 mL | ESV 60 mL |
The table gives an arterial pulse pressure, systolic minus diastolic, of 40 mmHg. Because the circuits are in series, right ventricular volumes equal left, but pulmonary resistance is much lower than total peripheral resistance (TPR) of the systemic circulation (Circulation Overview – Circuits, Vessels and the MAP Equation), so right ventricular and pulmonary artery pressures are far lower than LVP and AP. In other words, both sides process the same volumes at very different pressures.
7. Heart sounds and the ECG on the same timeline
Each valve closure is audible, so the heart sounds share this timeline. S1 is mitral before tricuspid closure (M1 before T1), a low, long 'lub', and S2 is aortic before pulmonary (A2 before P2), a short, high-pitched 'dub'. The third sound (S3), from passive filling in early diastole, is not heard in adults but may be in the young, and the fourth (S4), from rapid filling after atrial contraction, is not heard, both being detected by phonocardiography (microphone recording). On the ECG each electrical event precedes its mechanical one: the P wave (atrial depolarisation) precedes atrial contraction, the QRS complex (ventricular depolarisation) precedes ventricular contraction, and the T wave is ventricular repolarisation (The ECG – Conduction, Leads and the Hexaxial System).

The Wiggers diagram stacks all of this on one time axis (0 to 1 s), so reading down any vertical line gives a single instant. The top rows give the valve events and phases. The pressure panel (mmHg) holds the black aortic trace (80 to 120, with the incisura), the red left ventricular trace and the atrial trace, whose a wave is atrial contraction, c wave the closing AV valve bulging back into the atrium and v wave the atrium filling against the closed AV valve in systole. Below run ventricular volume (EDV to ESV, the gap labelled SV), aortic flow velocity (above zero only during ejection), the phonocardiogram and the ECG. The lesson is that every valve event is a crossing of two pressure traces: rising past atrial and then aortic pressure, ventricular pressure shuts the mitral and opens the aortic valve, and falling back past them it shuts the aortic and opens the mitral valve.
8. Murmurs
Between these sounds healthy valves are silent, because normal flow is laminar (stream-lined), whereas turbulent flow is heard as a murmur, an important sign of valve lesions: narrowing (stenosis) or reversed flow (insufficiency or incompetence). A stenosis murmur sounds while its valve should be open, an incompetence murmur while it should be shut.
- In aortic stenosis the murmur is systolic, between S1 and S2, peaking at mid-systole.
- In mitral incompetence the murmur lasts throughout systole.
- In aortic incompetence the murmur comes in early diastole.
- In mitral stenosis the murmur is low-pitched and mid-diastolic.
Plotted as pressure against volume, the same cycle becomes the loop of Pressure–Volume Loop, Starling’s Law and Contractility, where aortic valve closure and S2 sit at the top-left corner.
Summary
Summary
Passive valves divide the cycle into diastole (isovolumetric relaxation, 80% passive filling and atrial contraction adding the last 20%) and systole (isovolumetric contraction, 0.05 s, starting with S1, then ejection, 0.3 s). Each ventricle swings between an EDV of about 130 mL and an ESV of about 60 mL, ejecting 70 mL on both sides, but at 120/80 mmHg in the aorta against 25/8 mmHg in the pulmonary artery. Semilunar closure gives S2 and the dicrotic notch and ends systole. Faster rates shorten diastole most, so at about 180 per minute it is shorter than systole. Murmurs are turbulent flow through a stenosed or incompetent valve.